All articles

Skin Tightening

Do At-Home Radiofrequency Devices Work? What RF Is, How to Use It, Who Should Avoid It

Sığ cam kapta şeffaf jel içinde üç yarı saydam katman; en alttaki katman ılık kehribar renginde parlıyor

What does an at-home radiofrequency device do? The short answer

An at-home radiofrequency device passes a weak alternating current through a head that you glide over the skin, warming it by a few degrees. The aim is to support the gradual reorganization of collagen with this gentle warm stimulus and to help skin look firmer and smoother. These products, also searched for as a facial radiofrequency device or simply an RF facial device, are a much lower-energy relative of the treatment given in a clinic.

What does the evidence say? Human studies of home RF report small but measurable changes in fine lines, skin thickness and firmness measurements. However, these studies had 20 to 70 participants, lasted 4 to 12 weeks, and many had no control group. A realistic expectation is a modest improvement seen over a few months of regular use.

What is it not? A home device is not a facelift, and it is not the home equivalent of clinic radiofrequency. The clinical system described in one review runs on a 330-watt generator; in the home-device studies that reported power, the value was between 5 and 12 watts.

Same name, different procedure. The "radiofrequency ablation" that often appears in search results is a separate medical procedure. According to Cleveland Clinic, in this procedure a doctor uses heat delivered through a needle or a fine tip to deliberately damage nerve tissue that carries pain, swollen nasal turbinates (conchae) or tumor tissue. Everything below concerns only cosmetic use in skin care.

What is radiofrequency? Current, resistance and heat

Radiofrequency is a form of energy. According to the 2022 review by Delgado and Chapas, radiofrequency is non-ionizing radiation at the low-energy end of the electromagnetic spectrum. In cosmetic devices this energy is used as an electric current that keeps changing direction between electrodes touching the skin. 1 MHz means the current completes one million full cycles per second; clinical monopolar systems usually run at 6 MHz.

Heat is born inside the tissue. As the current changes direction, charged particles and polar molecules such as water in the tissue oscillate back and forth. The tissue's resistance to this movement turns electrical energy into heat. As Elsaie's review underlines, under the right conditions what heats up is the tissue itself, not the electrode.

The formula is simple. The energy produced is the product of the square of the current, the resistance of the tissue and time: E = I² × R × t. Doubling the current quadruples the heat produced. Holding the head twice as long in the same spot also doubles the energy delivered to that spot; this is the physics behind the "do not stay in one spot" warning on home devices.

Not every tissue heats the same. According to the 2025 review by Zhang and colleagues, resistance rises from water to nerve, muscle, collagen and most of all fat, so fatty tissue heats up more at the same current. Delgado and Chapas write that in laboratory measurements at 1 MHz, conductivity decreases from blood to moist skin, dry skin, fat and, least of all, bone. Elsaie also reminds us that the water content of skin changes with the time of day, ambient humidity and the moisturizer you use. So the same setting may not give the same heat every day.

Why does skin color not matter? Lasers and light look for a colored target (a chromophore); radiofrequency does not. According to the 2020 review by Dayan and colleagues, because the heat follows the tissue's resistance and not its color, the method can be used on all skin types. Frequency, on the other hand, affects depth: according to Delgado and Chapas, the lower the frequency, the deeper the energy goes.

Monopolar, bipolar, multipolar, RF microneedling: what changes with the path of the current?

Clear water in a shallow glass tray; fine rings spreading from two points meet in a shallow arc
Rings spreading from two points and meeting in between show how, in bipolar radiofrequency, the current takes a shallow path between two electrodes.

What really separates radiofrequency devices is the path the current takes through the skin. The number and arrangement of the electrodes determine how deep the heat goes and who can use the device safely.

Type Electrode arrangement Approximate depth of effect Where is it used?
Monopolar One active tip; the current passes through the body to a grounding pad placed far away Up to 20 mm In the clinic, with surface cooling
Bipolar Two electrodes in the same head; the current passes only between the two About half the distance between the electrodes, mostly 1-4 mm In the clinic and at home
Multipolar Three or more electrodes; the positive pole changes hands in sequence Slightly deeper than bipolar In the clinic and at home
RF microneedling The current is delivered from the tips of needles that pierce the skin About 0.5-2 mm in the face In the clinic only

Monopolar. There is a single active tip; the current passes through the body and reaches a grounding pad stuck on a distant part of the body. According to Delgado and Chapas, because this arrangement heats tissue over a wide volume it is an effective option for laxity, but it is more uncomfortable than bipolar systems. Zhang and colleagues give the depth of effect as up to 20 mm; cooling is needed to protect the upper layer of skin.

Bipolar. Two electrodes sit in the same head, and the current does not spread to the rest of the body. The depth of effect is roughly half the distance between the electrodes. Zhang and colleagues give this as mostly 1-4 mm and write that the more controlled energy distribution makes bipolar RF suitable for home use.

Multipolar. Three or more electrodes are used. According to Delgado and Chapas, the positive pole changes hands between the electrodes at short intervals; this rotation helps prevent any single electrode from overheating and carries the heat slightly deeper than a bipolar arrangement. Most of the home-device studies we read were done with bipolar or multipolar devices.

RF microneedling. Here the current is delivered from the tips of fine needles that pierce the skin, and the tissue between the needles is left intact. The 2023 review by Shauly and colleagues recommends needle depths for the face of 0.5 mm around the lips, 1 mm over the cheekbone area and 1.5 mm on the forehead and neck. These numbers also show how close to the surface the targeted dermis lies.

In its October 2025 safety communication, the US Food and Drug Administration (FDA) stated that RF microneedling is a medical procedure, not a cosmetic treatment. The agency says it has received reports of burns, scarring, fat loss, disfigurement and nerve damage, and that these devices should not be used at home.

Focused ultrasound is a different technology. Another method used in clinics for lifting uses sound waves instead of electric current; according to the American Academy of Dermatology (AAD), dermatologists use ultrasound to send heat to deep layers. You can find how home ultrasonic devices differ from this clinical procedure in our guide to ultrasonic skincare devices and the difference from HIFU.

What temperature does collagen need? Heat, time and depth

A row of four small glass beakers; the gel in them warms from pale turquoise to deep amber
The row of gel warming from pale to dark shows that collagen responds differently to different temperatures and that too much heat approaches a burn.

Collagen responds to heat in two stages. The collagen molecule is a helix of three chains wound around each other and held together by hydrogen bonds. According to the review by Dayan and colleagues, when heat breaks these bonds the fibers shorten and thicken right away. A wound-healing process then follows; over the next 3-4 months new collagen forms and elastin is reorganized. The first effect is immediate; the part expected to last takes months.

Temperature and time are interchangeable. There is no single "collagen temperature." According to Dayan and colleagues, collagen contraction needs more than 85°C for millisecond contact, while 60-65°C is enough for contact of a few seconds. For every 5°C drop in temperature, about 10 times longer is needed for a similar effect. To reduce burn risk, Zhang and colleagues also suggest applying lower heat for longer, for example about 43°C for 3-5 minutes.

Condition What does it mean? Source
1 millisecond at 85°C or 3 seconds at 67°C Threshold for permanent structural change in collagen Zhang et al., 2025
65-68°C under the skin, 38-42°C at the surface Distribution found necessary for best contraction in clinical and animal studies Dayan et al., 2020
About 43°C for 3-5 minutes Gentle heat aimed at remodeling while lowering burn risk Zhang et al., 2025
37-42°C at the skin surface Range held by a sensor in one home-device study Shu et al., 2022

This is where the clinic and the home device part ways. Clinical monopolar devices target deep tissue with strong heat and protect the surface with a cooling spray; Delgado and Chapas write that with such devices the skin surface is kept below 45°C. Home devices keep the surface in a warm range with a sensor. In the home-device studies we reviewed, how many degrees the dermis reached was not measured; what was controlled or reported was the temperature of the skin surface.

More is not better. According to Delgado and Chapas, overheating progresses in order from redness to swelling, blistering and full-thickness burns. The logic of a home device is not to deliver high heat in one go but to provide a mild heat stimulus repeated over weeks. Remember that the loss is slow too: by the estimate in Elsaie's review, adult skin loses about 1% of its dermal collagen per year.

Clinic RF vs at-home radiofrequency devices: power, depth, sessions

Does a home radiofrequency device do the clinic's job on a smaller scale? Partly. Both groups use the same physics, but power, depth and the way it is applied are very different.

Clinic monopolar RF Home bipolar or multipolar RF
Who applies it? A doctor, in the clinic The person, at home
Generator power 330 W in the system described in one review About 5-12 W in the devices in the studies
Frequency Usually 6 MHz 1 MHz in the devices in the studies
Depth of effect From 3 mm to 20 mm depending on the device Mostly 1-4 mm
Surface protection Cooling spray Temperature and motion sensors
Session pattern Usually a single session, repeated if needed 2-5 times a week for 4-12 weeks
When is the best result? At about 6 months according to the AAD Studies measured at 4-12 weeks

The power gap is large. Elsaie's review writes that a clinical monopolar system works with a 330 W, 6 MHz generator and carries heat to a depth of 3-6 mm. The devices in home studies are far lower in power: the device tested by Shemer and colleagues delivered 12 W at a frequency of 1 MHz, and the one used by Ai and colleagues delivered 5.22-6.25 W. The 2021 systematic review by Cohen and colleagues recommends, for home RF, a power of 10-12 W, used every other day for 1-2 months.

The safety design is different too. The home device studied by Shu and colleagues reduced or stopped its power when skin temperature rose, and it cut off energy if the head stayed motionless for a while. Clinical devices instead balance high energy with physician supervision and cooling.

For this reason a home device does not replace clinic treatment. It is a separate care tool that works with lower energy, spread over a more frequent and longer schedule.

What do people who had radiofrequency say? Measurement is not the same as satisfaction

One of the key studies of clinic RF is the multicenter study published by Fitzpatrick and colleagues in 2003. 86 people received a single monopolar RF session around the eyes and were followed for 6 months. The study was run with the support of the device manufacturer.

The gap between photographs and the eye. Blinded evaluators saw an improvement of at least 1 point in wrinkle score in 83.2% of the treated periorbital areas. Physicians who evaluated without looking at earlier photographs noticed improvement in only 28.9% of the areas. 50% of participants said they were satisfied or very satisfied with the result.

Change measured in millimeters. 61.5% of the eyebrows rose by at least 0.5 mm. On the safety side, second-degree burns were seen in 0.36% of treatments and 3 people had a small scar at month 6.

This picture explains why reviews of radiofrequency treatment differ so much. A half-millimeter change detected by measurement is not always noticeable in the mirror. In the 12-month study by Bassichis and colleagues, summarized in the review by Dayan and colleagues, 64% of 24 people did not perceive a cosmetic benefit after a single session.

The wider picture is cautious too. The 2021 systematic review by Paggiaro and colleagues examined 25 randomized studies testing RF for aesthetic purposes. The authors found quality problems such as selection and assessment bias and could not identify a level of evidence that would put RF ahead of other options. In the 2025 review by Kumar and colleagues, satisfaction rates in 13 studies ranged from 82% to 100%; the authors list small samples and the lack of control groups among the most frequent limitations.

Does an at-home radiofrequency device work? What the human studies show

There are published human studies on home RF, but all of them are small and short. We can summarize the studies we read like this:

Study Participants and design Use What it found
Shemer et al., 2014 69 people (62 completed), no control group 4 weeks, at least 5 times a week Improvement of at least 1 point in wrinkle score in 92-98% of participants according to three dermatologists
Sadick and Harth, 2016 47 people (45 completed), no control group 12 weeks, 3 times a week at first, then 2 Improvement in firmness and elasticity measurements; mild redness lasting at most 15 minutes
Shu et al., 2022 33 women, randomized split-face; the other half got an anti-aging cream 12 weeks, supervised, 6 minutes per session More improvement than the cream in wrinkles, radiance and skin thickness; no difference between the two sides in hydration and elasticity
Ai et al., 2023 22 women, open-label, no separate control group 8 weeks, 3 times a week Periorbital wrinkle score fell from 2.74 to 2.35; dermal thickness increased
Wanitphakdeedecha et al., 2022 24 people, split-face; RF, red LED and microcurrent together 8 weeks, 2 times a week No significant change in wrinkle size, depth or facial volume; skin texture became smoother
Omi, 2018 20 women, no control group 4 weeks, every other day Self-assessment score for sagging rose from 1.99 to 5.60, then fell back to 4.53 2 weeks after stopping

What does this table say? First, participant numbers are between 20 and 70 and follow-up is at most a few months. Second, many studies have no control group, and the two studies that did make a comparison had different results. Third, the changes are small: in the study by Ai and colleagues the periorbital wrinkle score changed by less than half a point in 8 weeks.

The reviews stop at the same place. The 2021 systematic review by Cohen and colleagues collected 37 clinical studies testing home devices and could find only one randomized controlled trial of home RF for wrinkles. Although the authors recommend low-power RF for wrinkles, they stress that long-term efficacy and safety data are lacking.

Combined devices make interpretation harder. The device in Shu and colleagues combined RF with 630 nm red light and used a gel with active ingredients on the device side; the device in Wanitphakdeedecha's study also had LED and microcurrent. It is hard to separate how much of such a result comes from radiofrequency. We gathered the evidence for red light separately in our guide to what each wavelength does in at-home LED light therapy.

The effect lasts with use. Omi's small study shows that perceived benefit began to fade within two weeks after use stopped. It is therefore more accurate to think of home RF as a care habit than as a course of treatment.

We explain how radiofrequency differs from red light, and which one suits which skin need, in our guide comparing radiofrequency and red light.

Radiofrequency skin tightening and RF facelift: how long, how much result?

Twelve clear serum drops curving across an ivory glass surface, each slightly larger than the one before
The growing drops show how, with at-home radiofrequency, results build up slowly over weeks.

An "RF facelift" is not surgery. The name is an everyday term for treatments that aim to tighten skin by stimulating collagen with heat; it does not mean a surgical lift. According to the AAD, the most noticeable result comes from a surgical facelift; even methods that enter the skin with a needle or fine tube cannot deliver the result of facelift surgery. The 2021 review by O'Connor and colleagues also regards surgery as the gold standard for laxity and reports mild to moderate improvement in most people with non-surgical tightening.

Who benefits more? According to the AAD, people with a little sagging get the best result; with pronounced sagging, skin tightening may not help. O'Connor and colleagues also write that results are better in younger people with mild to moderate laxity. We explained the bone, fat and connective tissue causes of sagging in detail in our guide to the causes of sagging facial skin and what works at home. The only layer home radiofrequency can reach among these is the skin.

The timeline in the clinic. According to the AAD, most people feel some tightness right after a single session, but because collagen production takes time, the best result appears at about 6 months. Some people benefit from more than one session, and the result can last 2-3 years with proper care. Cleveland Clinic, for its part, writes that the change is seen in 2-6 months and that some people need 2-6 sessions.

A realistic timeline at home. Because a home device has low power, the timeline depends on the pattern of sessions:

  • First sessions. Expect a warm feeling and brief mild redness. In the study by Sadick and Harth the redness lasted at most 15 minutes.
  • Week 4. Some studies caught the first measurable difference at this point.
  • Weeks 8-12. Most studies measured the result in this range. It is the reasonable earliest point for judging.
  • After you stop. Regular use is needed to keep what you gained; perceived benefit may fade when you take a break.

How to use radiofrequency at home: safe step-by-step use

Your device's manual always comes first: power, duration and whether the skin should be dry or gelled vary by device. The recommendations Delgado and Chapas list for clinical practice (start with a low setting, use a low setting over bony prominences and curved areas, watch the skin's response, do not rush) offer a framework that also works at home.

  1. Prepare the skin. Remove makeup and creams. If the manual calls for dry skin, dry the skin thoroughly; if it calls for gel, use only the recommended gel. Moist skin conducts better than dry skin, so this choice changes the heating.
  2. Start at the lowest level. In the first sessions try a small area on the cheek and watch how the skin responds for a day.
  3. Keep moving. Glide the head in slow, upward circles. Staying in one spot builds up heat.
  4. Lower the level near bone. Use a lower level on thin, curved areas such as the forehead, cheekbone and jawline.
  5. Use sensation as your measure. Mild warmth is normal. If you feel burning, stinging or pain, stop.
  6. Stick to the duration and frequency. In the studies, sessions lasted 6 to 18 minutes and were done 2 to 5 times a week; do not go beyond the limit of your own device.
  7. Stay away from the eyes. Do not apply it to the eyelid or over the eyeball.
  8. Clean the head. After the session, wipe and dry the application surface as the manual says.

What should you look for when choosing a device? The device studied by Shu and colleagues had two basic safety measures: a temperature sensor that reduced power as the skin warmed, and a motion sensor that cut energy if the head stayed still. To weigh which technologies a device combines and who it suits, take a look at our skincare brands guide that compares home devices, serums and clinic treatment brands.

Common mistakes: staying in one spot, too many sessions, wrong expectations

Holding the head in one spot. According to Delgado and Chapas, the main causes of overheating are too much energy and hot spots where the energy is not evenly distributed. Even if your device has a temperature sensor, keep the head moving continuously.

Extending the time. Because heat and time are interchangeable, a longer session or repeated passes over the same area bring the heat dose closer to the burn threshold. Treat the session time in your manual as a ceiling, not a target.

Pushing the heat until it hurts. Even in the clinic the goal is a feeling that is "hot but not painful." The 2011 review by Polder and Bruce recommends telling patients that the treatment should feel hot but not hot enough to cause pain. At home the bar is lower: mild warmth is enough.

Applying to broken or infected skin. O'Connor and colleagues list an open wound, and Polder and Bruce an active skin infection, among the barriers to RF. Skip areas with a rash or open wound until they heal.

Judging after two weeks. The tightness felt in the first days is not the change that comes later; the AAD also stresses that even in the clinic the best result comes months later. Telling whether a line is an expression line or an established wrinkle sets your expectations correctly; you can find the difference in our guide to at-home methods for wrinkles and realistic expectations.

Ignoring redness. In a registry review of more than 600 clinical treatments cited by Polder and Bruce, the most frequent side effect was redness and swelling lasting less than 24 hours. If at home you see redness lasting more than a day, blistering or discoloration, your setting is too high for you; stop using it.

Who should not use radiofrequency, and when to see a dermatologist

The safety limits of radiofrequency come largely from the current passing through tissue. In the following situations, do not use a home device or talk to your doctor first:

  • Pacemakers, ICDs and other active electronic implants. According to Delgado and Chapas, RF is mostly contraindicated in people with pacemakers and implantable defibrillators (ICDs) because of the risk of interaction with the device. The manufacturer's label for a clinical RF device also writes that these devices may be adversely affected by the RF field or current.
  • Metal implant in the treatment area. Polder and Bruce recommend asking about metal parts such as metal implants, plates and braces and avoiding treatment over those areas.
  • Pregnancy and breastfeeding. According to O'Connor and colleagues, pregnancy is a barrier because there are not enough studies in this group. Two of the home-device studies we read also explicitly excluded pregnant women.
  • Open wound, active infection, rash. Do not apply until the area has healed.
  • Cancer. O'Connor and colleagues also list malignant disease in the treatment area among the barriers; if you have a history of cancer, talk to your doctor first.
  • Filler, autoimmune disease, epilepsy. The manufacturer of a clinical RF device states that the device has not been studied on areas with filler, in pregnant and breastfeeding women, in diabetes, in autoimmune diseases such as lupus, in people with a history of cold sores or epilepsy, over permanent makeup and tattoos, and in children. If any of these applies to you, ask your doctor first.

When should you see a dermatologist? If you notice blistering, crusting, redness lasting more than a day, discoloration or hardening under the skin, stop using the device and see a dermatologist. For pronounced sagging or a newly appeared swelling on the face, you need an examination, not a home device.

For LED, ultrasound, heat and cold modes, we list who should take extra care in our guide to the safety of at-home skincare devices.

How does Longos Sense use radiofrequency?

In Longos Sense, which combines six technologies in a single body, the Radiofrequency (RF) mode is bipolar and works at a frequency of 1 MHz; in other words, it belongs to the group of home devices described above. According to the user manual, RF is applied from Surface 1 of the device. The cosmetic indication in the manual reads: to temporarily warm skin tissue with the aim of improving the appearance of the skin.

  • How? Surface 1 is applied to dry skin and moved in slow, upward circles. A mild feeling of warmth is normal; stop if you feel discomfort.
  • How often? 3-4 times a week, 5-10 minutes per session.
  • At what level? Intensity is chosen from 1 to 6 on the device; the manual recommends starting at a low level.
  • What to watch for? Holding RF still in one spot can cause local heat build-up and burns, so the device is always moved slowly and continuously. It is not used over the eyes and eyelids, while charging, or over a rash or open wound.
  • Who should not use it? The manual lists people with active electronic implants, people with a metal implant in the treatment area, pregnant and breastfeeding women and those under 18 among the contraindications. People who use blood thinners are asked to talk to their doctor first.

The Thermal Therapy mode on the same device works differently: the module on Surface 2 warms the skin surface by contact, and the contact surface reaches at most 39°C. Radiofrequency, on the other hand, produces heat inside the tissue with current. For this reason we keep expectations limited to the cosmetic wording in the manual: the studies above were done with other devices, with their own protocols, and their results cannot be transferred directly to any device.

Where to start this week

Record a starting point today: take photos of your face from the front and the side in front of the same window at the same time of day. If you start with radiofrequency at home, stay with the frequency in the manual for 12 weeks and only then compare against these photos. If you have pronounced sagging, start with a dermatologist's examination instead of waiting for these 12 weeks.

If you want a measurement in addition to photos, run the AI skin analysis in the Longos Sense app once on clean, product-free skin and note the wrinkle and fine line score as your baseline. This is a care guide, not medical advice; if you see blistering or redness that does not go away, stop using the device and talk to your dermatologist.

Frequently Asked Questions

What is radiofrequency and what does it do to skin?

Radiofrequency is a non-ionizing, low-energy form of electromagnetic energy. In cosmetic devices it is delivered as an alternating current that cycles millions of times per second between electrodes touching the skin. The resistance of the tissue to this current turns electrical energy into heat. The heat quickly shortens collagen fibers and then starts a remodeling process that lasts for months. Unlike lasers, RF does not look for a colored target, so it can be used on all skin types. Radiofrequency ablation, which doctors use to destroy nerve, nasal turbinate or tumor tissue, is a separate procedure.

Does an at-home radiofrequency device work?

Small studies show a modest benefit. In human studies of home RF, participants numbered 20 to 70 and the duration was 4 to 12 weeks; these studies reported small but measurable changes in fine lines, skin thickness and firmness measurements. However, many had no control group, one split-face study found no change in wrinkle depth, and a 2021 systematic review could find only one randomized controlled trial of home RF for wrinkles. The effect lasts with regular use and may fade when you stop. A home device does not replace clinic treatment or a facelift.

How do you use radiofrequency at home, and how many times a week?

First follow your device's manual, because power, duration and whether the skin should be dry or gelled vary by device. Start on clean skin at the lowest level; keep the head moving in slow upward circles and do not stay in one spot. Mild warmth is normal; if you feel burning or pain, stop. In published studies sessions lasted 6 to 18 minutes and were done 2 to 5 times a week. Do not use it on the eyelid, and treat the session time in the manual as a ceiling, not a target.

What is an RF facelift, and does it replace surgery?

RF facelift is an everyday name for treatments that aim to tighten skin by heating it with radiofrequency and stimulating collagen; it is not a surgical lift. According to the American Academy of Dermatology, the most noticeable result comes from a surgical facelift, and skin tightening helps most people who have only a little sagging; it may not help with pronounced sagging. Clinical reviews also report mild to moderate improvement in most people with non-surgical tightening. Low-power home devices are an even gentler care tool than clinic treatment.

When does radiofrequency give results, and is the effect permanent?

In the clinic most people feel some tightness after a single session, but according to the American Academy of Dermatology, collagen production takes time, so the best result appears at about 6 months and can last 2-3 years with proper care. Studies with home devices measured results between 4 and 12 weeks; a reasonable earliest point for judging is weeks 8-12. In one small study, perceived benefit began to fade two weeks after use stopped. Skin keeps aging, so no result lasts forever.

Who should not use radiofrequency?

People with a pacemaker, an implantable defibrillator or another active electronic implant should not use radiofrequency. If there is a metal implant, plate or screw in the treatment area, do not apply it there. Pregnancy and breastfeeding are not recommended because there is not enough research. An open wound, active infection, rash or a malignant disease in the treatment area also rule it out. If you take blood thinners, have recently had filler, or have epilepsy or an autoimmune condition, ask your doctor first. If you get blistering or redness that does not go away, stop using it and see a dermatologist.

Clinical evidence

Measure your skin. See the change.

The Longos Skin Score measures your skin from 0 to 100. Longos Sense and 8 serums deliver the care it needs at home, in just a few minutes.

Discover Longos Sense

The set's serums are pre-selected; swap any you like. You can pick the same serum more than once.